Laserfiche WebLink
PLN17-0069 874 Lewelling Blvd - 6-Unit Townhome Development - Zoning Amendment, Planned Development, Site Plan Review, Tentative Map <br />EXHIBIT F - FIRE ACCESS <br />N orth <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />NOPARKING <br />UNIT 1 <br />BLDG HEIGHT = 35.3 <br />EAVE HEIGHT = 28.0 UNIT 5 <br />BLDG HEIGHT = 24.75'EAVE HEIGHT = 19.00' <br />KEYNOTES <br />ADA ACCESSIBLE AISLE 8' x 19' <br />CONCRETE WALKWAY <br />ELECTRICAL UTILITY BOX <br />ADA RAMP <br />DECORATIVE GRAVEL AREA <br />GATE ACCESSIBLE FOR FIRE ACCESS, NO LOCK <br />TRUNCATED DOMES <br />ADDRESS MINIMUM 6" MONUMENT SIGN <br />ADDRESS MINIMUM 4" ILLUMINATED SIGN <br />PROJECT SIGNAGE, SEE SHEET G0.0# <br />ACCESSIBLE PARKING SIGN, <br />ACCESSIBLE PARKING TOW AWAY SIGN, <br />STD. 42' FIRE TRUCK <br />MULTIFAMILY MAIL BOX <br />GATE ACCESSIBLE FOR FIRE ACCES, NO LOCK <br />SIGN FOR FIRE EGRESS, NO LOCK <br />NO PARKING SIGN <br />BIKE RACK 5' - 0"PER CFC 2016 APPENDIX D10120' - 6"3 <br />G006 <br />6 <br />TYP. <br />FIRE SAFETY NOTES <br />1.ALL BUILDINGS SHALL BE INSTALLED WITH AUTOMATIC FIRE SPRINKLER SYSTEM NFPA 13D SINGLE FAMILY <br />MONITORED SYSTEM.FIRE PERMITS ARE REQUIRED FOR FIRE SPRINKLER INSTALLATION AND UNDERGROUND FIRE <br />SERIVCE LINES. <br />2.FIRE ACCESS ROADS SHALL BE DESIGNED AND MAINTAINED TO SUPPORT THE IMPOSED LOAD OF FIRE APPARATUS75,000 LBS, SUBSURFACE MATERIAL TO HAVE 95% COMPACTION AND SHALL BE DESIGNED AND SURFACED AS TO <br />PROVIDE ALL-WEATHER DRIVING CAPABILITY. <br />3.ADDRESSING OF THE BUILDINGS SHALL BE IN COMPLIANCE WITH FIRE DEPARTMENT REQUIREMENTS: MINIMUM 4 <br />INCH SELF-ILLUMINATING ADDRESS INSTALLED ON THE FRONT OF EACH BUILDING &/OR UNIT AS TO BE VISIBLEFROM THE STREET. A DECORATIVE ADDRESS MONUMENT SIGN SHALL BE INSTALLED AT THE ENTRANCE, <br />INDICATING THE BUILDING ADDRESSES FOR THE UNITS SERVED BY SUCH COURT. MINIMUM SIZE NUMBERS SHALL <br />BE 6 INCHES IN HEIGHT ON A CONTRASTING BACKGROUND. <br />4.PRIOR TO CERTIFICATE OF OCCUPANCY, CONTACT THE FIRE MARSHAL'S OFFICE (510) 577-3317 AT LEAST 24 <br />HOURS BEFORE THE DESIREDD REQUIRED FINAL INSPECTION APPOINTMENT TO VERIFY THAT REQUIREMENTS FOR <br />THE FIRE PROTECTION FACILITIES HAVE BEEN MET & ACTUAL CONSTRUCTION OF ALL FIRE PROTECTION <br />EQUIPMENT HAVE BEEN COMPLETED IN ACCORDANCE WITH APPROVED PLAN.5.FIRE HYDRANTS FOR THE DEVELOPMENT SHALL BE OPERATIONAL AND IN SERVICE PRIOR TO THE START OF ANY <br />COMBUSTIBLE CONSTRUCTION AND /OR STORAGE OF COMBUSTIBLE CONSTRUCTION MATERIALS. <br />6.EMERGENCY EGRESS WINDOWS SHALL BE PROVIDED MEETING THE 65 DEGREE ANGLE STANDARDS. TALL <br />VEGETATION IS STRICTLY PROHIBTED BENEATH THESE WINDOWS/ AREAS.7.FIRE LANE SHALL SUPPORT LOAD OF 75,000 LBS. <br />MATERIALS & ABBREVIATIONS <br />ASPHALT CONCRETE <br />PERMEABLE PAVERS <br />PLANTING <br />FIRE ACCESS <br />FENCE 6'-0" <br />FIRE HOSE LENGTH <br />FIRE HYDRANT <br />NO PARKING FIRE LANE SIGNAGE, PER T29 <br />STOP SIGN, R1-1, SEE G008 FOR SPEC <br />FIRE SIGN, 150'-0" <br />NP <br />FH <br />UNIT 2 <br />BLDG HEIGHT = 35.3 <br />EAVE HEIGHT = 28.0 <br />UNIT 3 <br />BLDG HEIGHT = 35.3 <br />EAVE HEIGHT = 28.0 <br />UNIT 4 <br />BLDG HEIGHT = 35.3 <br />EAVE HEIGHT = 28.0 <br />11 <br />L=141' <br />UNIT 6BLDG HEIGHT = 24.75' <br />EAVE HEIGHT = 19.00' <br />2 <br />7 <br />3 <br />5 <br />8' - 0"10' - 0"8' - 0"7' - 0" <br />4 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />1 <br />PORTLAND CEMENT CONCRETE / COLOR LAMP BLACK / 6" MIN. <br />L=141'REQ. 10' X 6' PRIVATEOPEN SPACE13 <br />14 <br />15 <br />16 <br />BLDG A <br />BLDG B <br />12 <br />13 <br />9 <br />9 <br />17 <br />17 <br />9 <br />10 <br />8 <br />14 <br />2G0059 9 9 <br />FIRE ACCESS <br />150' - 0" <br />18 <br />18 <br />REQ. 10' X 6' PRIVATEOPEN SPACEGROUP OPEN SPACE <br />3038 SF <br />REQ. 10' X 6' PRIVATEOPEN SPACEREQ. 10' X 6' PRIVATEOPEN SPACEREQ. 10' X 6' PRIVATEOPEN SPACE REQ. 10' X 6' PRIVATEOPEN SPACE <br />S <br />3' - 0"21' - 0" <br />24' - 0" <br />RED CURB <br />150' - 0"47' - 9"NFNF NP <br />NP <br />STOP25' - 0"F <br />F <br />NO <br />PARKING <br />4 <br />G005 <br />S <br />2 <br />24' - 0"5 <br />3' - 0"13' - 9"65.0°BEDROOM <br />LIVING <br />STORAGE23' - 6"SIDEWALK <br />5' - 7" <br />FIRE ACCESS / DRIVEWAY <br />20' - 6" <br />BEDROOM <br />GARAGE <br />65.00°10' - 11 1/2"3' - 0"23' - 6 1/2"3' - 6" <br />HALLWAY <br />6 <br />5 <br />.0 <br />0 <br />°22' - 11"GARAGE <br />LIVING <br />BEDRM #3 <br />13' - 9" <br />3' - 0" <br />STORAGE ATTS <br />LAC <br />E <br />FO ILICENS E D ARCHIT <br />ECTF O RNIAGORD KONW <br />GNO <br />RENEWAL 08/17/2015 <br />4 0 4 53-C <br />Project Schedule RevisionSan Leandro, CA 94579874 Lewelling BoulevardSCALE Lewelling CondominiumsR E S I D E N T I A L / C O M M E R C I A LGKW ARCHITECTS, INC. AIA, LEED GA710E MCGLINCY LANE SUITE 109CAMPBELL CA 95008(408) 315-2125 LIC# 34045,WWW.GKWARCHITECTS.COMPROJECT REPRESENTATIVESJENNY C. WONG & WEIRAN JIA710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008(408) 796-1845 | WWW.GKWARCHITECTS.COMRENEWAL 08/17/2019 <br />1 <br />No.Date Description <br />2018.08.08 Planning <br />2 2019.01.07 Planning <br />3 2019.03.25 Planning <br />4 2019.07.11 Planning <br />7/10/2019 6:06:06 PM <br />As indicated <br />G006 <br />Fire Access Analysis & <br />SignageFire Access Analysis & Signage 1" = 10'-0"1 Fire Access Analysis & Signage <br /> 1/4" = 1'-0"2 Fire Ladder Apparatus <br />0'5'10'20'40' <br /> 1/4" = 1'-0"3 Section 6 <br />SECTION, FIRE LADDER, BUILDING A <br /> 1/4" = 1'-0"4 Bldg A, Ladder Access, Rear Central Units <br />SECTION, FIRE LADDER, BUILDING A SECTION, FIRE LADDER, BUILDING A <br />EBMUD FIRE SERVICE AVAILABLE FLOW & PRESSURE INFORMATION <br />FIRE NOTE <br />1. A FIRE FLOW REDUCTION OF UP TO 50 PERCENT IS <br />ALLOWED WHEN THE BUILDING IS PROVIDED WITH <br />AUTOMATIC SPRINKLER IN ACCORDANCE WITH NFPA 13. <br />THE RSULTING FIRE FLOW SHALL NOT BE LESS THAN 1,500GMPS PER 2016 CALIFORNIA FIRE CODE TABLE B105.1 <br />24