My WebLink
|
Help
|
About
|
Sign Out
Home
Reso 2019-173
CityHall
>
City Clerk
>
City Council
>
Resolutions
>
2019
>
Reso 2019-173
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2019 12:33:53 PM
Creation date
12/6/2019 12:33:46 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Resolution
Document Date (6)
10/21/2019
Retention
PERM
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXHIBIT B TO RESOLUTION NO. 2019 - <br /> <br />FINDINGS AND DETERMINATION THAT CHANGES <br />OR MODIFICATIONS TO THE 2019 CALIFORNIA BUILDING CODE, ARE <br />REASONABLY NECESSARY BECAUSE OF LOCAL CONDITIONS <br /> <br />1. In connection with the adoption by reference of the International Building Code, <br />2018 Edition, as amended by the State of California in that document entitled “The California <br />Building Standards Code,” it is hereby expressly found and determined that the following <br />changes are reasonably necessary because of local climatic, geological or topographical <br />conditions: <br /> <br />Section 7-5-140 Table R602.10.3(3) (Bracing Requirements Based on Seismic Design <br />Category) of CRC Chapter 6 (Wall Construction) is amended as follows: <br /> <br /> Add a new “g” footnote notation to the end of CRC Table R602.10.3 (3). To read: <br /> <br />f. In Seismic Design Categories D0, D1, and D2, Method GB is not permitted and the use <br />of Method PCP is limited to one-story single family dwellings and accessory <br />structures. <br /> <br />Add the “g” footnote notation in the title of Table R602.10.3(3) to read: <br /> <br />Section R602.10.4.5 is added to Section R602.10.4 (Construction methods for braced <br />wall panels) of CRC Chapter 6 (Wall Construction), to read: <br /> <br />R602.10.4.5, to read: <br /> <br />R602.10.4.5 Limits on methods GB and PCP. In Seismic Design Categories D0, D1, and D2, <br />Method GB is not permitted for use as intermittent braced wall panels, but gypsum board is <br />permitted to be installed when required by this Section to be placed on the opposite side of the <br />studs from other types of braced wall panel sheathing. In Seismic Design Categories D0, D1, and <br />D2, the use of Method PCP is limited to one-story single family dwellings and accessory structures. <br /> <br />Section 7-5-145: MULTIPLE HAZARDS: OUTDOOR STORAGE. <br /> <br />(a) When a hazardous material has multiple hazards, all hazards shall be addressed and <br />controlled in accordance with the provisions of this chapter. When overhead noncombustible <br />construction is provided for sheltering exterior hazardous material storage areas, such storage shall <br />not be considered indoor storage when all of the following conditions are met: <br />(1) Supports shall be of noncombustible construction. <br />(2) Supports and walls shall not obstruct more than 25 percent of the perimeter of the storage <br />area. <br />(3) The distance to buildings, property lines, streets, alleys, public ways or exits to a public way <br />shall not be less than the distance required for an exterior hazardous material storage area <br />without weather protection. <br /> <br />Section 7-5-155: Noncombustible construction Section 414.6.1.3 of the Code is added to read
The URL can be used to link to this page
Your browser does not support the video tag.