Laserfiche WebLink
Page 12 of 16 <br /> <br />5451 Chavenelle Road, Dubuque, Iowa 52002 ◼ [O] 563.585.0967 ◼ www.unisonsolutions.com <br />Design and content included in this document is proprietary and remains the property of Unison Solutions, Inc. <br />MAINTENANCE <br /> <br />- Hydrogen Sulfide Removal System <br /> <br />- Replace Foam Pad <br />- Replace Hydrogen Sulfide Media <br />- Estimated Cost = $19,500.00* <br />- Estimated Media Life = 275 days @ 1,000ppm <br />*Labor for change out, disposal and shipping of media not included <br /> <br />- Gas Compression/Moisture Removal System <br /> <br />- Clean Gas Compressor Inlet Moisture/Particulate Filter <br />- Clean/Replace Oil Particulate Filter <br />- Change Oil Filter <br />- Change Compressor Oil <br />- Clean Oil Heat Exchanger <br />- Clean Glycol Chiller Condenser <br />- Test Glycol for Freeze Point <br />- Estimated Cost = $5,000*every 12 months <br />*Technician Labor and travel expenses not included <br /> <br />ESTIMATED ELECTRICAL PARASITIC <br /> <br />- Electrical Parasitic <br /> <br />- Gas Compressor Motor = 76 kW <br />- Oil Cooler Motor = 2 kW <br />- Glycol Chiller = 30 kW <br />- Controls & Auxiliary Equipment = 4 kW <br />Total = 112 kW (Full Load) <br />Total = 90 kW (Average Run Load) <br /> <br /> <br />DocuSign Envelope ID: 1DDC1773-ED91-404B-97DD-AC3EFDBAD0DD