My WebLink
|
Help
|
About
|
Sign Out
Home
9G Consent
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2022
>
Packet 01182022
>
9G Consent
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2025 10:32:40 AM
Creation date
4/1/2022 9:40:15 AM
Metadata
Fields
Template:
CM City Clerk-City Council
Retention
PERM
Document Relationships
Reso 2022-017 Updated Sewer System Mgmt Plan
(Amended)
Path:
\City Clerk\City Council\Resolutions\2022
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
City of San Leandro <br />Sewer System Management Plan <br />Volume I <br /> <br />Page | 30 <br /> <br /> <br />Section 8 – System Evaluation and Capacity Assurance Plan <br />D.13.(viii) System Evaluation and Capacity Assurance Plan: The Enrollee shall prepare and implement a <br />capital improvement plan (CIP) that will provide hydraulic capacity of key sanitary sewer system <br />elements for dry weather peak flow conditions, as well as the appropriate design storm or wet weather <br />event at a minimum, the plan must include: <br /> (a) Evaluation: Actions needed to evaluate those portions of the sanitary sewer system that are <br />experiencing or contributing to an SSO discharge caused by hydraulic deficiency. The evaluation <br />must provide estimates of peak flows (including flows from SSOs that escape from the system) <br />associated with conditions similar to those causing overflow events, estimates of the capacity of <br />key system components, hydraulic deficiencies (including components of the system with limiting <br />capacity), and the major sources that contribute to the peak flows associated with overflow <br />events; <br /> (b) Design Criteria: Where design criteria do not exist or are deficient, undertake the evaluation <br />identified in “a” above to establish appropriate design criteria; and <br /> (c) Capacity Enhancement Measures: The steps needed to establish a short- and long-term capital <br />improvement plan (CIP) to address identified hydraulic deficiencies including prioritization, <br />alternatives analysis, and schedules. The CIP may include increases in pipe size, I/I reduction <br />programs, increases and redundancy in pumping capacity, and storage facilities. The CIP shall <br />include an implementation schedule and shall identify sources of funding. <br /> (d) Schedule: The Enrollee shall develop schedule of completion dates for all portions of the capital <br />improvement program developed in (a-c) above. This schedule shall be reviewed and updated <br />consistent with the SSMP review and update requirements as described in Section D. 14. <br /> <br />The City periodically conducts flow monitoring and hydraulic modeling analysis to anticipate <br />future growth or increased demand on the system as well as the City's internal inspection, <br />rehabilitation and repair program to assure that excessive I/I is not impacting the capacity of the <br />system. <br />The City’s previous sanitary sewer master plan was completed in 1995. Since that time, the City <br />has completed a number of sewer improvement projects and is experiencing development in a <br />number of areas necessitating an evaluation of the capacity of the sanitary sewer system to <br />handle future flows. A new Sanitary Sewer Capacity Study and Master Plan (Appendix D) was <br />completed in 2015 to confirm existing flows in the collection system and anticipate capital needs <br />for capacity improvement. In addition, it satisfies the requirement for the Sewer System Master <br />Plan to include a System Evaluation and Capacity Assurance Plan. <br />Capacity Assurance Program <br />The capacity assurance process is used to determine estimated peak flows associated with wet <br />weather conditions causing overflow events, estimates of the capacity of key system <br />117
The URL can be used to link to this page
Your browser does not support the video tag.