My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda Packet
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2022
>
Packet 03212022
>
Agenda Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2022 12:18:11 PM
Creation date
4/1/2022 12:15:08 PM
Metadata
Fields
Template:
CM City Clerk-City Council
Retention
PERM
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
378
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
the tracking of sediment onto the public right-of-way. Inspections, conducted as <br />part of the regular construction compliance, will be conducted to ensure <br />compliance of the Applicant and contractors with this requirement. <br />Off-Site Improvement Conditions: <br />E. The Applicant shall obtain an Encroachment Permit from the Engineering and <br />Transportation Department for any work within the Public Right-of-Way. <br />Site Conditions: <br />F. The Applicant shall place all utilities serving the site underground. <br />VII. ALAMEDA COUNTY FIRE DEPARTMENT REQUIREMENTS <br />The following conditions shall be met prior the issuance of a building permit and fire <br />clearance for occupancy: <br />A. A Deferred Submittal is required for the Fire Protection System. A deferred <br />approval is required for the fire sprinkler system. Any changes to the existing <br />fire sprinkler system requires a separate submittal, permit, plan review, <br />inspections and fees. <br />B. A Deferred Submittal is required if there is a Fire Alarm System. <br />C. No delayed egress is allowed in the building without the installation of a Fire <br />Detection system throughout the entire building and notification. <br />D. Emergency lighting and Exit signs will be needed. <br />E. Exit door hardware shall comply with Sections 1010.1.9 and 1010.1.9.3 of the <br />2016 California Building Code. All hardware on the doors shall be lever, panic, <br />or paddle. <br />F. Fire extinguishers are to be shown on the plans submitted for approval. <br />Minimum rating of fire extinguishers is 2A10B:C. Fire extinguishers are to be <br />located near exits in the normal path of egress. Travel distance to fire <br />extinguishers shall not exceed 75 feet. <br />G. A fire department key box is to be shown on the plans submitted for approval. <br />H. Address with a contrasting background. <br />I.A Knox Box. <br />Agreement to Conditions November 2,2017 <br />PLN 17-0012 Page 9 of 14
The URL can be used to link to this page
Your browser does not support the video tag.