My WebLink
|
Help
|
About
|
Sign Out
Home
12A Public Hearings
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2022
>
Packet 11072022
>
12A Public Hearings
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2025 2:24:41 PM
Creation date
11/10/2022 12:50:51 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Agenda
Document Date (6)
11/7/2022
Retention
PERM
Document Relationships
Ord 2022-014 Building Code Update
(Amended)
Path:
\City Clerk\City Council\Ordinances\2022
Reso 2022-230 Building Code Standards and Reach Codes
(Amended)
Path:
\City Clerk\City Council\Resolutions\2022
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
159
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1803.10 Final Report. Before final inspection for any building or structure, the <br />Geotechnical Engineer or Civil Engineer in responsible charge of the soil investigation shall <br />issue a final report stating the completed pad, foundation, finish grading, drainage, and <br />associated site work substantially conforms to the approved plans, specifications, and <br />investigation. <br />7-5-180 CONCRETE AND MASONRY FOUNDATION WALLS. <br /> Section 1807.1.6 of the 2022 California Building Code is amended to read as follows: <br />1807.1.6 Prescriptive design of concrete and masonry foundation walls. Concrete and <br />masonry foundation walls that are laterally supported at the top and bottom shall be <br />permitted to be designed and constructed in accordance with this section. Prescriptive <br />design of foundation walls shall not be used for structures assigned to Seismic Design <br />Category D, E or F. <br />7-5-185 MODIFICATIONS TO ACI 318. <br /> The last paragraph of Section 1905.1.2 of the 2022 California Building Code is amended to <br />read as follows: <br />All special moment frames and special structural walls shall also satisfy 18.2.4 through <br />18.2.8. Concrete tilt-up wall panels classified as intermediate precast structural wall system <br />shall satisfy 18.10.1 in addition to 18.5.2.1 and 18.5.2.2 for structures assigned to Seismic <br />Design Category D, E or F. <br /> 1905.1.7 ACI 318, Section 14.1.4 of the 2022 California Building Code is amended in its <br />entirety to read as follows: <br />14.1.4 – Plain concrete in structures assigned to Seismic Design Category C, D, E or F. <br />14.1.4.1 – Structures assigned to Seismic Design Category C, D, E or F shall not have <br />elements of structural plain concrete, except as follows: <br />(a) Isolated footing of plain concrete supporting pedestals or columns are permitted, provided <br />the projection of the footing beyond the face of the supported member does not exceed the <br />footing thickness. <br /> Exception: In detached one- and two-family dwellings three stories or less in height, the <br />projection of the footing beyond the face of the supported member is permitted to exceed the <br />following thickness. <br />(b) Plain concrete footing supporting walls are permitted, provided the footings have at least <br />two continuous longitudinal reinforcing bars. Bars shall not be smaller than No.4 and shall have <br />a total area of not less than 0.002 times the gross cross-sectional area of the footing. A minimum
The URL can be used to link to this page
Your browser does not support the video tag.