My WebLink
|
Help
|
About
|
Sign Out
Home
12A Public Hearings
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2022
>
Packet 11072022
>
12A Public Hearings
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2025 2:24:41 PM
Creation date
11/10/2022 12:50:51 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Agenda
Document Date (6)
11/7/2022
Retention
PERM
Document Relationships
Ord 2022-014 Building Code Update
(Amended)
Path:
\City Clerk\City Council\Ordinances\2022
Reso 2022-230 Building Code Standards and Reach Codes
(Amended)
Path:
\City Clerk\City Council\Resolutions\2022
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
159
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
of one bar shall be provided at the top and bottom of the footing. Continuity of reinforcement <br />shall be provided at corners and intersections. <br />Sections 1905.1.9 through 1905.1.11 are added to Chapter 19 of the 2022 California Building <br />Code as follows: <br /> 1905.1.9 ACI 318, Section 18.7.5. Modify ACI 318, Section 18.7.5, by adding <br />Section 18.7.5.8 and 18.7.5.9 as follows: <br />18.7.5.8 Where the calculated point of contra-flexure is not within the middle half of the <br />member clear height, provide transverse reinforcement as specified in ACI 318 <br />Sections 18.7.5.1, Items (a) through (c), over the full height of the member. <br />18.7.5.9 At any section where the design strength, φPn, of the column is less than the sum <br />of the shears Ve computed in accordance with ACI 318 Sections 18.6.5.1 and 18.7.6.1.1 for <br />all the beams framing into the column above the level under consideration, transverse <br />reinforcement as specified in ACI 318 Sections 18.7.5.1 through 18.7.5.3 shall be provided. <br />For beams framing into opposite sides of the column, the moment components are permitted <br />to be assumed to be of opposite sign. For the determination of the design strength, φPn, of <br />the column, these moments are permitted to be assumed to result from the deformation of <br />the frame in any one principal axis. <br /> 1905.1.10 ACI 318, Section 18.10.4. Modify ACI 318, Section 18.10.4, by adding <br />Section 18.10.4.6 to read as follows: <br />18.10.4.6 – Walls and portions of walls with Pu > 0.35Po shall not be considered to <br />contribute to the calculated shear strength of the structure for resisting earthquake-induced <br />forces. Such walls shall conform to the requirements of ACI 318 Section 18.14. <br /> 1905.1.11 ACI 318, Section 18.12.6. Modify ACI 318, Section 18.12.6.2, as follows: <br />18.12.6.2 Collector and boundary elements in topping slabs placed over precast floor and <br />roof elements shall not be less than 3 inches (76 mm) or 6 db in thickness, where db is the <br />diameter of the largest reinforcement in the topping slab. <br />7-5-190 CONVENTIONAL LIGHT-FRAME CONSTRUCTION. <br /> Section 4.3.4 of SDPWS 2015 Edition is amended as follows: <br /> Delete rows 5 and 6 of Table 4.3.4. <br /> Section 2306.3 of the California Building Code, 2022 is amended as follows: <br />2306.3 Wood-frame shear walls. Wood-frame shear walls shall be designed and <br />constructed in accordance with AWC SDPWS. Where panels are fastened to framing <br />members with staples, requirements and limitations of AWC SDPWS shall be met and the
The URL can be used to link to this page
Your browser does not support the video tag.