My WebLink
|
Help
|
About
|
Sign Out
Home
5G Consent
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2024
>
Packet 20240220
>
5G Consent
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2024 4:16:04 PM
Creation date
2/23/2024 4:28:39 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Staff Report
Document Date (6)
2/20/2024
Retention
PERM
Document Relationships
Gates & Associates, Inc CSA 20240305
(Amended)
Path:
\City Clerk\City Council\Agreements\2024
Reso 2024-012 Gates and Associates for Shoreline Park Project
(Amended)
Path:
\City Clerk\City Council\Resolutions\2024
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />■ Design and submit PG&E preliminary electric drawings, including job instructions and <br />material summary <br />■ Create material lists associated with electric drawings <br />■ Coordinate with AT&T and Comcast <br />■ Obtain AT&T and Comcast designs for inclusion into composite and redraft them for <br />clarity using the latest civil background <br />■ Complete joint trench design, create composite drawings and ‘Form B’ <br />■ Design trench cross sections, indicating occupancy for each utility, and show street <br />cross section that depicts joint trench location relative to face of curb <br />■ Design future fiber (CLEC) conduit system <br />■ Design updates and submittals, per city comments, <br />○ Layout Enlargements <br />○ Irrigation Plans <br />○ Environmental graphic sign details, messaging, and sections. <br />○ Electrical Plans <br />■ Power to pre-fabricated building (stub-up only) <br />■ Lighting Controls <br />■ EV chargers and power infrastructure <br />■ Irrigation Controller power provision and Power bollards at Park <br />■ Vehicular and pedestrian pole luminaire design layout <br />■ Convenience power locations <br />○ Telecommunication Plans <br />■ WiFi Access points and associated Infrastructure <br />■ WiFi capacity and coverage planning <br />○ Structural plans, details, and calculations for: <br />■ Assessment, anchoring, foundations for 3 existing sculptures and memorials which are <br />to be relocated on site: Lost Boat memorial, Oyster Beds Mosaic, and Jack D <br />Malstester Channel Commemoration plaque <br />■ Light post footings - vehicular and pedestrian <br />■ Structural support/bracing for electrical equipment as needed <br />■ Foundations for Pre fabricated restroom buildings <br />■ Provide structural coordination of landscape elements including: Site retaining walls at <br />grading perimeter conforms, and Vehicular Gate (1). <br />■ Gateway monument sign support and foundations, design services <br />○ Construction details for all civil, electrical, landscape and structural work <br />● Prepare 65% Cost Estimate <br />● Prepare 65% Project Specifications <br />● Provide Draft 65% QC/QA set for internal coordination and review. <br />● Perform verified Quality Control/ Quality Assurance review of the entire plan set. <br />● Integrate QC/QA review comments into final 65% PS&E submittal. <br />Subtask 4.2– 100% PS&E <br />● Perform a geotechnical review of the 100% plans <br />● Coordinate a Joint Resolution Team (JRT) meeting to review 50% Design Development Plans and <br />Estimate to gain concurrence as to how the documents will be revised as appropriate to incorporate <br />City comments.
The URL can be used to link to this page
Your browser does not support the video tag.