Laserfiche WebLink
Attachment ATable A‐1Soil Sampling Analytical ResultsWaste Water Pollution Control Plant, Waste Water Treatment Wetland Project, City of San Leandro, San Leandro, CaliforniaLocationField Sample IDCollection Depth (ft bgs)Sample DateCommentsSoil Direct Exposure Construction Worker ESLsSoil Leaching to GW, Drinking Water ESLsSoil Leaching to GW, Non‐Drinking Water ESLsWetland Foundation Material Conc GuidelinesPetroleum HydrocarbonsDiesel Range Organics‐‐1100 1100 7300Gasoline Range Organics‐‐1800 1100 4900Motor Oil‐‐54000‐‐ ‐‐Polychlorinated BiphenylsAroclor‐1254‐‐ ‐‐ ‐‐ ‐‐Aroclor‐1260‐‐ ‐‐ ‐‐ ‐‐PCBs (total) 0.18 5.5 330 330MetalsAntimony‐‐50‐‐ ‐‐Arsenic 0.07 0.98‐‐ ‐‐Barium‐‐3000‐‐ ‐‐Beryllium‐‐27‐‐ ‐‐Cadmium 0.0096 51‐‐ ‐‐Chromium (total) 0.37‐‐ ‐‐ ‐‐Chromium VI‐‐2.8‐‐ ‐‐Cobalt‐‐28‐‐ ‐‐Copper 0.27 14000‐‐ ‐‐Cyanide (total)‐‐22 0.0034 0.0034Lead 0.218 160‐‐ ‐‐Mercury 0.0007 44‐‐ ‐‐Molybdenum‐‐1800‐‐ ‐‐Nickel 0.12 86‐‐ ‐‐Perchlorate‐‐250‐‐ ‐‐Selenium‐‐1700‐‐ ‐‐Silver 0.0037 1800‐‐ ‐‐Thallium‐‐3.5‐‐ ‐‐Vanadium‐‐470‐‐ ‐‐Zinc 0.41 110000‐‐ ‐‐Notes:123#, B, C, and Y are unknown qualifiers.4567Abbreviations:ND ‐ Not DetectedNA ‐ Not AnalyzedJ ‐ Estimated ConcentrationV ‐ The sample concentration is too high to evaluate accurate spike recoveries.P ‐ RPD between the primary and confirmatory analysis exceeded 40%.P1 ‐ RPD value not applicable for sample concentrations less than 5 times the reporting limit.J3 The associated batch QC was outside the established quality control range for precision.J4 The associated batch QC was outside the established quality control range for accuracy.J5 The sample matrix interfered with the ability to make any accurate determination; spike value is high.J6 The sample matrix interfered with the ability to make any accurate determination; spike value is low.O1 ‐ The analyte failed the method required serial dilution test and/or subsequent post‐spike criteria.        These failures indicate matrix interference.Blue boldfaced concentrations exceed the Soil Leaching to GW, Non‐Drinking Water ESLs.All concentrations reported in mg/kg (ppm); detection limits in parentheses.Only compounds with at least one detection are shown.Underlined concentrations exceed the Wetland Foundation Material Conc Guidelines.Double underlined concentrations exceed the Soil Direct Exposure Construction Worker ESLs.Gray‐shaded concentrations exceed the Soil Leaching to GW, Drinking Water ESLs.SB‐02 SB‐03 SB‐04 SB‐05 SB‐06 SEC A EAST 1 SEC A EAST 1 SEC A EAST 2 SEC A EAST 2SB‐02A‐SB02D SB‐03A‐SB‐03B SB‐04A‐SB‐04D SB‐05A‐SB‐05C SB‐06A‐SB‐06C SEC A EAST 1 BOTTOM SEC A EAST 1 TOP SEC A EAST 2 BOTTOM SEC A EAST 2 TOP‐‐ ‐‐ ‐‐ ‐‐ ‐‐ ‐‐3.0 ‐ 4.0‐‐3.0 ‐ 4.02/7/2017 2/7/2017 2/8/2017 2/8/2017 2/8/2017 5/5/2021 5/5/2021 5/5/2021 5/5/2021NA NA NA NA NA 422 J;V 10.9 195 J 217 JNA NA NA NA NA 0.144 ND (0.116) 0.184 ND (0.112)NA NA NA NA NA 1100 44.2 703 1100NA NA NA NA NA ND (0.0193) ND (0.0198) ND (0.0198) ND (0.019)NA NA NA NA NA ND (0.0193) 0.0873 6.69 3.06NA NA NA NA NA ND (0.0386) 0.0873 6.693.06NA NA NA NA NA 4.98 1.52 JND (2.32) 6.64311NA 3.9NA 8.049.435.5111290 290 160 140 170 241 266 574 514NA NA NA NA NA 0.27 0.464 0.277 0.3235.67.61.92.62.12.222.986.921596345464939.763.471.8107NA NA NA NA NA ND (2.27) ND (2.33) ND (2.32) ND (2.23)9.5 8.9 9.1 8.6 9.1 14.2 15.6 16.6 13.6130140366050300103121462NA NA NA NA NA0.161 J 0.185 J 0.341 0.603120031045907927417520612000.180.440.10.230.120.290.1420.3150.8490.91 4.7 NA NA NA 0.513 J 0.989 1.54 5.67473950545946.673.363.379.1NA NA NA NA NA ND (0.0454) ND (0.0465) 0.0339 JND (0.0447)NA NA NA NA NA ND (2.27) ND (2.33) ND (2.32) ND (2.23)0.831.2NA 0.510.520.327 J0.414 J1.622.01NA NA 1.7 NA NA ND (2.27) ND (2.33) ND (2.32) ND (2.23)34 42 31 30 33 50.3 51.2 75.7 52.4410400791601403313242891200Page 8 of 22Terraphase Engineering Inc.