Laserfiche WebLink
Page 38 of 68 <br /> <br />of one bar shall be provided at the top and bottom of the footing. Continuity of reinforcement <br />shall be provided at corners and intersections. <br /> <br />Sections 1905.1.9 through 1905.1.11 are added to Chapter 19 of the 2025 California Building <br />Code as follows: <br /> <br />1905.1.9 ACI 318, Section 18.7.5. Modify ACI 318, Section 18.7.5, by adding <br />Section 18.7.5.8 and 18.7.5.9 as follows: <br /> <br />18.7.5.8 Where the calculated point of contra-flexure is not within the middle half of the <br />member clear height, provide transverse reinforcement as specified in ACI 318 <br />Sections 18.7.5.1, Items (a) through (c), over the full height of the member. <br /> <br />18.7.5.9 At any section where the design strength, φPn, of the column is less than the sum <br />of the shears Ve computed in accordance with ACI 318 Sections 18.6.5.1 and 18.7.6.1.1 for <br />all the beams framing into the column above the level under consideration, transverse <br />reinforcement as specified in ACI 318 Sections 18.7.5.1 through 18.7.5.3 shall be provided. <br />For beams framing into opposite sides of the column, the moment components are permitted <br />to be assumed to be of opposite sign. For the determination of the design strength, φPn, of <br />the column, these moments are permitted to be assumed to result from the deformation of <br />the frame in any one principal axis. <br /> <br />1905.1.10 ACI 318, Section 18.10.4. Modify ACI 318, Section 18.10.4, by adding <br />Section 18.10.4.6 to read as follows: <br /> <br />18.10.4.6 – Walls and portions of walls with Pu > 0.35Po shall not be considered to <br />contribute to the calculated shear strength of the structure for resisting earthquake-induced <br />forces. Such walls shall conform to the requirements of ACI 318 Section 18.14. <br /> <br />1905.1.11 ACI 318, Section 18.12.6. Modify ACI 318, Section 18.12.6.2, as follows: <br /> <br />18.12.6.2 Collector and boundary elements in topping slabs placed over precast floor and <br />roof elements shall not be less than 3 inches (76 mm) or 6 db in thickness, where db is the <br />diameter of the largest reinforcement in the topping slab. <br /> <br />7-5-190 CONVENTIONAL LIGHT-FRAME CONSTRUCTION. <br /> <br />Section 4.3.4 of SDPWS 2015 Edition is amended as follows: <br /> <br />Delete rows 5 and 6 of Table 4.3.4. <br /> <br />Section 2306.3 of the California Building Code, 2025 is amended as follows: <br /> <br />2306.3 Wood-frame shear walls. Wood-frame shear walls shall be designed and <br />constructed in accordance with AWC SDPWS. Where panels are fastened to framing <br />members with staples, requirements and limitations of AWC SDPWS shall be met and the <br />Resolution No. 2025-152