My WebLink
|
Help
|
About
|
Sign Out
Home
Reso 2025-152 Building Code Findings
CityHall
>
City Clerk
>
City Council
>
Resolutions
>
2025
>
Reso 2025-152 Building Code Findings
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/26/2025 5:02:58 AM
Creation date
11/26/2025 5:01:58 AM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Resolution
Document Date (6)
11/17/2025
Retention
PERM
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 39 of 68 <br /> <br />allowable shear values set forth in Table 2306.3(1), 2306.3(2) or 2306.3(3) shall be <br />permitted. The allowable shear values in Tables 2306.3(1) and 2306.3(2) are permitted to be <br />increased 40 percent for wind design. Panels complying with ANSI/APA PRP-210 shall be <br />permitted to use design values for Plywood Siding in the AWC SDPWS. Shear walls <br />sheathed with Portland cement plaster, gypsum lath, gypsum sheathing or gypsum board <br />shall not be used to resist seismic forces in structures assigned to Seismic design Category <br />D, E or F. <br /> <br />Section 2308.6.8.1 of the 2025 California Building Code is amended as follows: <br /> <br />2308.6.8.1 Foundation Requirements. Braced wall lines shall be supported by continuous <br />foundations. <br /> <br />Exceptions: <br /> <br />1. One-story buildings with maximum plan dimension not exceeding 50 feet (15240 mm), may <br />have continuous foundations located at exterior braced wall lines only. <br /> <br />2. Two-story buildings with a maximum plan dimension not exceeding 50 feet (15240 mm) <br />may have braced wall lines supported on continuous foundations at the exterior walls only, <br />provided: <br /> <br />a. Cripple walls do not exceed 4 feet (1219 mm) in height. <br /> <br />b. Where the first story is supported on a raised wood framed floor, the interior braced <br />wall panels are directly supported by either doubled joists, continuous 4x blocking or <br />minimum 4x floor beams. <br /> <br />7-5-195 REPAIRS. <br /> <br />Title 24, California Existing Building Code, Part 10, Sections 404.2.4 through 404.2.4.2 and <br />Tables 404.2.4.1 and 404.2.4.2 are added as follows: <br /> <br />404.2.4 Seismic Evaluation and Design Procedures for Repairs. The seismic evaluation <br />and design shall be based on the procedures specified in the California Building Code, <br />ASCE 31 Seismic Evaluation of Existing Buildings (for evaluation only) or ASCE 41 <br />Seismic Rehabilitation of Existing Buildings. The procedures contained in Appendix A of <br />the International Existing Building Code shall be permitted to be used as specified in <br />Section 3405.5.1.1.3. <br /> <br />404.2.4.1 Compliance with CBC level seismic forces. Where compliance with the seismic <br />design provisions of the California Building Code is required, the procedures shall be in <br />accordance with one of the following: <br /> <br />1. One-hundred percent of the values in the California Building Code. Where the existing <br />seismic force-resisting system is a type that can be designated as “Ordinary,” the values of R, <br />Resolution No. 2025-152
The URL can be used to link to this page
Your browser does not support the video tag.