Laserfiche WebLink
<br />EXHIBIT A-2 <br />DETAILS OF DELIVERABLES <br /> <br />The City of San Leandro has a standard title block and standard size sheet (24"x36"). <br />The contractor shall use both for all sheets of the plans. The title block will be provided <br />in ACAD format. <br /> <br />Standard plans that are referenced on this project shall be included on the plan sheets of <br />the construction documents. Standard details are available in .tif format on the City web <br />site; they shall be inserted into electronic files and printed without changes. <br /> <br />Details, plans, elevations, etc. shall be arranged and nun1bered on the sheets in a regular <br />consistent pattern. All sub-consultants shall make their work conform with the detail <br />nun1bering convention of the Consultant. <br /> <br />Specifications shall be written and printed with times new roman font at 11 point <br />minimum. Specifications shall be edited such that only materials, procedures, and <br />execution specific to this project are included. <br /> <br />Iten1s to be precast or prefabricated shall be so noted on plans. Plans shall differentiate <br />between field welding and shop welding. <br /> <br />All plans shall be drafted in accordance with Consultant's CAD standards. Text shall not <br />be written over lines or other text. Existing items/workJfeatures shall be clearly labeled <br />as such. Text shall plot at 3/32" tall minin1um. Details shall not be called as similar <br />unless the actual detail clearly notes what occurs at the similar location. Details shall be <br />cut with the proper orientation. Details with reverse orientation shall be noted as OH <br />(opposite hand) on the drawings. Words shall be completely spelled out unless an <br />abbreviation is defined on the drawings. <br /> <br />Electronic file for specifications shall be provided in MSW ord format. <br /> <br />Electronic files for drawings shall be provided in AutoCad (Autodesk) format. <br /> <br />300/0 Construction Plans are defined to include the following: <br />Title Sheet <br />List of proposed drawings <br />Site plan showing all known existing utilities that can be obtained fron1 existing <br />drawings, proposed utility points of connection, and potential utility conflicts <br />Layout sheets (All plan sheets from all disciplines) <br />Sufficient design to prove concept <br />All plans are expected to have the city standard title block <br /> <br />700/0 Construction Plans are defined to include the following: <br />All itelTIS from 30o~, updated <br /> <br />WPCP Electrical, \V AS, Flow EQ <br />593-52-225 <br /> <br />Page 21 of24 <br />