My WebLink
|
Help
|
About
|
Sign Out
Home
3A Public Hearing 2007 1119
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2007
>
Packet 2007 1119
>
3A Public Hearing 2007 1119
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2019 8:11:15 AM
Creation date
11/15/2007 4:48:37 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Staff Report
Document Date (6)
11/19/2007
Retention
PERM
Document Relationships
_CC Agenda 2007 1119
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2007\Packet 2007 1119
MO 2007-078
(Reference)
Path:
\City Clerk\City Council\Minute Orders\2007
MO 2007-079
(Reference)
Path:
\City Clerk\City Council\Minute Orders\2007
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DD. If the design of any site improvements requires encroachments onto <br />neighboring properties during construction, written agreements with that <br />property owner shall be submitted to the City Engineer, for review and <br />approval, prior to issuance of the building permits. <br />EE. During construction the following high standards for sanitation are required: <br />Garbage cans, construction dumpsters, and debris piles shall be removed on <br />a minimum weekly basis. All food related trash items such as wrappers, <br />cans, bottles, and food scraps shall be disposed of in closed containers only <br />and shall be regularly removed from the site. Inspections, conducted as part <br />of the regular construction compliance, will be conducted to ensure <br />compliance of the Applicant and contractors with this requirement. <br />V. PROJECT SITE IMPROVEMENTS <br />A. All garages shall have electronic, remote control garage door openers. <br />B. All electrical, gas, and water meters shall be located such that they will not <br />be visible from the street or common driveway, or these units shall be <br />screened or enclosed. The screen or enclosure shall be painted to match the <br />color of the exterior building wall that it is affixed to. <br />C. Within the habitable areas of the dwellings, exterior sound transmission <br />control measures shall be provided to prevent the intrusion of exterior <br />noise. Prior to approval of building permits, the developer shall submit <br />evidence that interior noise levels attributable to exterior sources will not <br />exceed 45 dBA in any habitable room. The measures shall include the <br />proper wall construction, window glazing and weather-stripping, exterior <br />doors that are solid -core, well fitted and weather-stripped. In addition, <br />keeping the windows closed would necessitate the installation of <br />mechanical systems to ensure adequate ventilation is provided. <br />D. Prior to approval of the final building plans for building permits, the <br />developer shall submit evidence that all residences comply with Title 24 <br />Code, to the satisfaction of the Building Official. <br />E. All house plans shall be engineered by a registered structural engineer <br />retained by the developer. To minimize the risk of damage to any <br />development from strong ground shaking during an earthquake, structures <br />shall be constructed using the site-specific provisions of the most recent <br />construction code enforced by the City. <br />F. The developer shall employ the engineer responsible for the structural <br />design, or another engineer designated by the engineer responsible for the <br />structural design, to perform structural observation in accordance with the <br />building code. Structural observation means the visual observation of the <br />structural system, for general conformance to the approved plans and <br />specifications at significant construction stages and at completion of the <br />structural system. <br />PLN2007-00050 Page 7 of 12 <br />Recommended Conditions of Approval October 11, 2007 <br />
The URL can be used to link to this page
Your browser does not support the video tag.