Laserfiche WebLink
Evaluation of Aquatic Facilities <br />City of San Leandro <br />San Leandro High School <br />vi. One hour or less for a wading pool. <br />vii. Two hours or less for a temporary training pool. <br />viii. Six hours or less for all other types of public pools. <br />If the two pools are separated with independent mechanical equipment then the existing <br />filter system would be large enough to operate in a six-hour turnover rate. The pool <br />circulation pump would need to be replaced with a pump for the designed flow rate. A <br />second set of equipment would need to be supplied and installed for the training pool. <br />The estimate assumes that the underground piping is suspect and would be replaced when <br />the pool deck is replaced. <br />(Estimated Cost $29,000.00) <br />7. The pools lack the safety deck depth markers in violation of Title 24, Chapter 31B. <br />3109B.4 Water Depth Markers. The water depth shall be clearly marked at the <br />following locations: <br />a. maximum depth, <br />b. minimum depth, <br />c. each end, <br />d. at the break in the bottom slope between the shallow and deep portions of the pool <br />[see also Section 3108B.4J, and <br />e. on the perimeter of the pool at distances not to exceed 25 feet. <br />The deck depth markers should be added to the pool. (SEE EXHIBIT 25) <br />(Estimated Cost $4,500.00) <br />,~~ -t -- <br />Exhibit 25: San Leandro High Lacks Deck Depth Markers <br />November 2001 Aquatic Design Group, Inc. <br />