My WebLink
|
Help
|
About
|
Sign Out
Home
Agmt 2003 Collaborative Design Architects Inc
CityHall
>
City Clerk
>
City Council
>
Agreements
>
2003
>
Agmt 2003 Collaborative Design Architects Inc
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2009 10:43:23 AM
Creation date
8/18/2009 10:43:22 AM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Agreement
Document Date (6)
7/21/2003
Retention
PERM
Document Relationships
Reso 2003-182
(Approved by)
Path:
\City Clerk\City Council\Resolutions\2003
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXHIBIT A-2 <br />DETAILS OF DELIVERABLES <br />The City of San Leandro has a standard title block and standard size sheet (22"x34") <br />The contractor shall use both for all sheets of the plans. <br />Standard plans that are referenced on this project shall be included on the plan sheets of <br />the construction documents. Details will be provided in .tif format, they shall be inserted <br />into electronic files and printed without changes. <br />Dimensions shall be buildable. Concrete shall not be dimensioned tighter than %z" in plan <br />and'/4" vertical. Structural wood including all stud walls shall not be dimensioned tighter <br />than'/4". Structural steel shall not be dimensioned tighter than 1/8". Finish work <br />excepted. <br />Details, plans, elevations, etc. shall be arranged and numbered on the sheets in a regular <br />consistent pattern. <br />Specifications shall be written and printed with times new roman font at 11 point <br />minimum. Specifications shall be edited such that only materials, procedures, and <br />execution specific to this project are included. <br />All plans shall be drafted in accordance with Contractor's CAD standards. Text shall not <br />be written over lines or other text. Existing items/work/features shall be clearly labeled <br />as such. Text shall plot at 3/32" tall minimum. Details shall not be called as similar <br />unless the actual detail clearly notes what occurs at the similar location. Details shall be <br />cut with the proper orientation. Details with reverse orientation shall be noted as OH <br />(opposite hand) on the drawings. Words shall be completely spelled out unless an <br />abbreviation is defined on the drawings. <br />Main Library Bookstore Page 8 of 20 <br />Collaborative Design Architects, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.