Laserfiche WebLink
Infrastructure Mitigation Strategies <br />8 of11 <br />E _ -. M U z Res Agency <br />Ordinance or Resolution # (if existing <br />a <br />o a or Depart ment <br />program), Estimated Cost and <br />m n m .� (Requ if Exisling <br />Possible Funding Agency (d high <br />Specific Mitigation Strategy <br />,p Q @ Program. Existing <br />priority). Estimated Dale or <br />Z _ Q, m Program under <br />`m ` Y H <br />Cam pletion (d study), WHY if not <br />N Zy �., o a ,� s v � funded, Very High, <br />same as regional priority, OR Other <br />W W o 7 7 m 9 o = �° J_ , z U High, or Under Study) <br />Comments <br />d 8 <br />'Develop an approach and locations for various <br />FL <br />XX <br />Alameda County <br />watercourse hank protection strategies, including <br />Flood Control <br />for example, (1) an assessment of hanks to <br />District . <br />inventory areas that appear prone to failure, (2) <br />bank stabilization, including installation of rip rap, or <br />whatever regulatory agencies allow (3) stream bed <br />depth management using dredging, and (d) removal <br />of out- of-date coffer dams in rivers and tributary <br />streams- <br />d <br />Use reservoir sediment or read removal as one way <br />FL <br />XX <br />Alameda County <br />to increase storage for both flood control and water <br />Flood Control <br />. supply. <br />District <br />d-11 <br />Identify critical locally -owned bridges affected by <br />FL <br />XX <br />Alameda County <br />flooding and either elevate them to increase stream <br />Flood Control <br />Now and maintain critical ingress and egress routes <br />District <br />or mortify the channel to achieve equivalent <br />objectives. <br />d-12 <br />Provide or support the mechanism to expedite the <br />FL XX <br />Engineering & <br />Standard procedure <br />repair or replacement of levees that are vu In erahla <br />Transportation <br />to collapse from earth quak shaking or <br />liquefacti on, rodents, and other concerns, <br />particularly those protecting critical infrastructure. <br />FL XX <br />d <br />Ensure that utility systems in new developments are <br />Engineering & <br />Standard procedure <br />constructed in ways that reduce or eliminate flood <br />Transportation <br />damage. <br />F <br />d- 14 <br />Determine whether or not wastewater treatment <br />XX <br />Public Works and <br />timded funding has redirected <br />plants are protected from floods, . and if not <br />Engineering and <br />priorities at the present time. <br />investigate the use offlood- control berms to not <br />Transportation <br />only protect from stream or river flooding, but also <br />increase plant security- <br />FL <br />XX <br />Alameda County <br />d-15 <br />Work cooperatively with water agencies, flood <br />control districts, Cakrans, and local transportation <br />Flood Control <br />agencies to determine appropriate performance <br />District <br />criteria for watershed analysis. <br />F XX <br />Standard procedure <br />d-16 <br />Work for better cooperation among the patchwork <br />Engineering & <br />of agencies managing flood control issues. <br />FL <br />Transportation <br />d-17 <br />Imprwa monitoring of creek and watercour� flows <br />XX <br />Alameda County <br />to predict potential for flooding downstream by <br />Flood Control <br />working cooperatively with land owners and the <br />District <br />cities and counties in the watershed. <br />8 of11 <br />