My WebLink
|
Help
|
About
|
Sign Out
Home
Ord 2016-023
CityHall
>
City Clerk
>
City Council
>
Ordinances
>
2016
>
Ord 2016-023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2017 10:03:31 AM
Creation date
1/11/2017 1:51:11 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Ordinance
Document Date (6)
12/19/2016
Retention
PERM
Document Relationships
_CC Agenda 2016 1219 RG
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2016\Packet 2016 1219
8J Consent 2016 1219
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2016\Packet 2016 1219
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
903.2.3 Group E—Amended. <br />An automatic sprinkler system shall be provided for Group E occupancies as follows: <br />1. Throughout all Group E fire areas greater than 7,500 square feet (697 m2) in area. <br />2. Throughout every portion of educational buildings below the lowest level of exit <br />discharge serving that portion of the building. <br />Exception: An automatic sprinkler system is not required in any area below the <br />lowest level of exit discharge serving that area where every classroom throughout <br />the building has not fewer than one exterior exit door at ground level. <br />3. In rooms or areas with special hazards such as laboratories, vocational shops and <br />other areas where hazardous materials in quantities not exceeding the maximum <br />allowable quantity are used or stored. <br />4. Throughout any Group E structure greater than 7,500 square feet (69 m2) in area, <br />which contains more than one fire area, and which is separated into two or more <br />buildings by fire walls of less than 4 -hour fire -resistance rating without openings. <br />5. When the overall height of the building exceeds 45 feet. <br />6. For public school state -funded construction projects see Section 903.19. <br />903.2.4 Group F-1—Amended. <br />An automatic sprinkler system shall be provided throughout all buildings containing a Group F-1 <br />occupancy where one of the following conditions exists: <br />1. A Group F-1 fire area exceeds 7,500 square feet (697 m2). <br />2. A Group F-1 fire area is located more than three stories above the grade plane. <br />3. The combined area of all Group F-1 fire areas on all floors, including any <br />mezzanines, exceeds 7500 square feet (697 m2). <br />4. A Group F-1 occupancy used for the manufacture of upholstered furniture or <br />mattresses exceeds 2,500 square feet (232 m2). <br />5. When the overall height of the building exceeds 45 feet. <br />903.2.4.1 Woodworking operations <br />An automatic sprinkler system shall be provided throughout all Group F-1 occupancy fire <br />areas that contain woodworking operations in excess of 2,500 square feet in area (232 <br />m2) that generate finely divided combustible waster or use finely divided combustible <br />materials. [SFM]A fire wall of less than 4 -hour fire -resistance rating without openings, <br />or any fire wall with openings, shall not be used to establish separate fire areas. <br />903.2.7 Group M—Amended. <br />An automatic sprinkler system shall be provided throughout all buildings containing a Group M <br />occupancy where one of the following conditions exists: <br />1. A Group M fire area exceeds 7,500 square feet (697 m2). <br />ORDINANCE NO. 2016-023 <br />5 <br />