My WebLink
|
Help
|
About
|
Sign Out
Home
8E Consent 2021 0201
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2021
>
Packet 2021 0201
>
8E Consent 2021 0201
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2021 9:02:17 PM
Creation date
1/27/2021 9:02:04 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Agenda
Document Date (6)
2/1/2021
Retention
PERM
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
100325.8 - ELECTRICAL ENCLOSURE <br />An electric wiring enclosure for the 12 volt wiring shall be installed in the front wall of the driver's side upper body <br />compartment with a access panel. The dimensions of the enclosures shall be approximately 20" high, 14" wide, and 4" deep. <br />D/S UPPER BODY COMPARTMENT, FWD WALL <br />100326.2 - 12 VOLT ELECTRICAL SPECIFICATIONS <br />The following describes the low voltage electrical system on the apparatus including all panels, electrical components, <br />switches and relays, wiring harnesses and other electrical components. The apparatus manufacturer shall conform to the <br />latest Federal DOT standards, current automotive electrical system standards and the applicable requirements of the NFPA. <br />Wiring shall be stranded copper or copper alloy conductors of a gauge rated to carry 125 percent of the maximum current <br />for which the circuit is protected. Voltage drops shall not exceed 10 percent in all wiring from the power source to the using <br />device. The wiring and wiring harness and insulation shall be in conformance to applicable SAE and NFPA standards. The <br />wiring harness shall conform to SAE J-1128 with GXL temperature properties. Exposed wiring shall be run in a loom with a <br />minimum 289 degree Fahrenheit rating. Wiring looms shall be properly supported and attached to body members. Electrical <br />conductors shall be constructed in accordance with applicable SAE standards, except when good engineering practice <br />requires special construction. <br />All wiring connections and terminations shall provide positive mechanical and electrical connections and be installed in <br />accordance with the device manufacturer's instructions. When wiring passes through metal panels, electrical connections <br />shall be with mechanical type fasteners and rubber grommets <br />Wiring between cab and body shall be split using connectors or enclosed in a terminal junction panel allowing body removal <br />with minimal impact on the apparatus electrical system. Connections shall be crimp-type with heat shrink tubing with <br />insulated shanks to resist moisture and foreign debris such as grease and road grime. Weather resistant connectors shall be <br />provided throughout the system. <br />Electrical junction or terminal boxes shall be weather resistant and located away from water spray conditions. When <br />required, automatic reset breakers and relays shall be housed in the main body junction panel. <br />There shall be no exposed electrical cabling, harnesses, or terminal connections located in compartments, unless enclosed in <br />an electrical junction box or covered with a removable electrical panel. Wiring shall be secured in place and protected <br />against heat, liquid contaminants and damage. <br />Low voltage overcurrent protective devices shall be provided for the electrical circuits. The devices shall be accessible and <br />located in required terminal connection locations or weather resistant enclosures. Overcurrent protection devices shall be <br />automatic reset type suitable for electrical equipment and meet SAE standards. All electrical equipment, switches, relays, <br />terminals, and connectors shall have a direct current rating of 125 percent of maximum current for which the circuit is <br />protected. Electro-magnetic interference suppression shall be provided in the system as required in applicable SAE <br />standards. <br />The electrical system shall include the following: <br />Electrical terminals in weather exposed areas shall have a non-conductive grease or spray applied. All terminal plugs located <br />outside of the cab or body shall be treated with a corrosion preventative compound. <br />All electrical wiring shall be placed in a protective loom or be harnessed. <br />Exposed connections shall be protected by heat shrink material and sealed connectors. <br />Large fender washers shall be used when fastening equipment to the underside of the cab roof and all holes made in the <br />roof shall be caulked with silicone. <br />Electrical components installed in exposed areas shall be mounted in a manner that will not allow moisture to accumulate <br />inside. <br />A coil of wire must be provided behind an electrical appliance to allow them to be pulled away from mounting area for <br />inspection and service work. <br />All lights in a weather exposed area that have their sockets shall have corrosion preventative compound added to the socket <br />terminal area. <br />Warning lights shall be switched in the chassis cab with labeled rocker type switches located in an accessible location. <br />Individual rocker switches shall be provided only for warning lights provided exceeding the minimum level of warning lights <br />in either the stationary or moving modes. All electrical equipment switches shall be appropriately identified as to their <br />function and mounted on a switch panel mounted in the cab convenient to the operator. For easy nighttime operation, an <br />integral indicator light shall be provided to indicate when a circuit is energized. <br />Skeeter Brush Trucks Page 14 12/03/2020139
The URL can be used to link to this page
Your browser does not support the video tag.