Laserfiche WebLink
13  <br />  <br />handled by the City’s existing sewer system and treated at the San Leandro Water Pollution Control  <br />Plant (SLWPCP)” (p. 4‐131).  <br />However, review of the SLWPCP treatment process demonstrates that the facility utilizes anaerobic  <br />digesters.23 As a result, the model is incorrect in assuming that the Project’s wastewater would be  <br />treated entirely aerobically, and we cannot verify the revised wastewater treatment system  <br />percentages.   <br />These unsubstantiated changes present an issue, as each type of wastewater treatment system is  <br />associated with different GHG emission factors, which are used by CalEEMod to calculate the Project’s  <br />total GHG emissions.24 Thus, by including unsubstantiated changes to the default wastewater treatment  <br />system percentages, the model may underestimate the Project’s GHG emissions. .  GHG emissions may  <br />constitute a significant impact requiring adequate mitigation. At this time, the Standard Conditions of  <br />Approval and General Plan mitigation measures presented do not substantially mitigate such impacts.  <br />An EIRshould be prepared to adequately address and mitigate these impacts.   <br />Incorrect Application of Tier 4 Interim Mitigation <br />Review of the CalEEMod output files demonstrates that the “Callan and E 14th Street Infill Checklist  <br />Project Mitigated Construction” model assumes that the Project’s off‐road construction equipment fleet  <br />would meet Tier 4 Interim emissions standards (see excerpt below) (Appendix A, pp. 105‐106).   <br />  <br />23 “Anaerobic Digesters.” San Leandro Wastewater Treatment, City of San Leandro, available at:  <br />https://www.sanleandro.org/depts/pw/wpcp/virtual/tour9.asp.  <br />24 CalEEMod User Guide, available at: http://www.caleemod.com/, p. 45. <br />128