Laserfiche WebLink
18 <br /> <br />Appendix 3 – Preliminary Equipment Specification <br /> <br />The following specifications refer to the suggested plant design as presented in Appendix 1. <br /> <br />Component Specification Quant <br />ity <br />Respon <br />sibility <br />/ <br />Supply <br />by <br />Comments <br /> <br />Aspiral L5 <br />40 ft. special design tank 5 x T2 MABR <br />towers Coarse bubble diffusers <br />Internal piping, fittings and valves <br /> <br />1 <br /> <br /> <br /> <br />Flu <br />enc <br />e <br /> <br /> <br />Equipment Skid <br />Process air blower: 190 NCFM @ 0.725 <br />PSIG <br />1 To be installed on <br />external skid. <br />Skid NOT covered Mixing air blower: 117 NCFM @ 4.35 PSIG 1 <br />Aspiral feed pump 1 <br />Electrical and Control 1 Basic with optional <br />upgrade <br />Secondary effluent <br />dichlorination <br /> <br />To provide dechlorinated effluent to <br />Aspiral <br />1 <br /> <br /> <br />Ot <br />her <br />s <br />TBD <br />FOG trap 1 Necessary only if FOG <br />>60 mg/l <br />Concrete floor According to detailed design made by <br />certified constructor 1 TBD <br />Aspiral L5 Inlet & <br />Outlet Piping, <br />fittings and valves <br /> <br />According to detailed design 1 <br />1. Some of the equipment's specifications might change in accordance with the design detailed. <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />